Intergard® 276 is a two pack epoxy primer/undercoat/tie coat.
Intended uses
For use as a primer for dry internal spaces such as the accommodation and engine room, and on above water areas, as an undercoat/tie coat between anticorrosive primers and a wide range of top coats.
Colour | EGA080-White, EGA081-Blue, EGA085-Grey |
Finish / Sheen | Matt |
Part B (Curing Agent) | EGA089 |
Volume Solids | 47% ± 2% (ISO 3233:1998) |
Typical Film Thickness | 40 microns dry (85 microns wet) |
Theoretical Coverage | 11.75 m²/litre at 40 microns dft, allow appropriate loss factors |
Method of Application | Airless Spray, Conventional Spray |
Safety information | |
Flash Point (Typical) | Part A 23°C Part B 26°C Mixed 23°C |
VOC-EU | 293 g/kg¹ |
¹ EU Solvent Emissions Directive (Council Directive 1999/13/EC)
Surfacetemperature | 5 °C | 15 °C | 25 °C | 35 °C |
Touch Dry [ISO 9117/3:2010] | 45 mins | 40 mins | 30 mins | 20 mins |
Hard Dry [ISO 9117-1:2009] | 24 hrs | 20 hrs | 12 hrs | 12 hrs |
Pot Life | 20 hrs | 16 hrs | 8 hrs | 3 hrs |
Certification
When used as part of an approved scheme, this material has the following certification::
• Fire Resistance - Marine Equipment Directive compliant
Consult your International Paint representative for details.
Systems and compatibility
Consult your International Paint representative for the system best suited for the surfaces to be protected.
Surface preparations
Use in accordance with the standard Worldwide Marine Specifications.
All surfaces to be coated should be clean, dry and free from contamination.
High pressure fresh water wash or fresh water wash, as appropriate, and remove all oil or grease, soluble contaminants and other foreign matter in accordance with SSPC-SP1 solvent cleaning
As a primer for internal steelwork
Where necessary, remove weld spatter and smooth weld seams and sharp edges.Clean welds and damaged shop-primer by grit-blasting to Sa2 (ISO 8501-1:2007) or by power tooling to Pt3 (JSRA SPSS :1984) or St3 (ISO 8501-1:2007).
As an undercoat/tie coat
The primer surface should be clean, dry and free from all contamination. Areas of breakdown, damage etc. should be prepared to the specified standard (eg. Sa2½ (ISO 8501-1:2007)). Intergard 276 must be applied within the overcoated intervals specified (consult the relevant product data sheet)To avoid pin-holing over inorganic zinc silicate primers, Intergard 276 should be thinned by 15-25% with International GTA220.
Mixing | Material is supplied in two containers as a unit. Always mix a complete unit in the proportions supplied. Once the unit has been mixed it must be used within the working pot life specified. (1) Agitate Base (Part A) with power agitator. (2) Combine entire contents of Curing Agent (Part B) with Base (Part A) and mix thoroughly with power agitator. |
Mix Ratio | 4 volume(s) Part A to 1 volume(s) Part B |
Airless Spray | Recommended Tip Range 0.38-0.53 mm (15-21 thou) Total output fluid pressure at spray tip not less than 176 kg/cm² (2500 p.s.i.) |
Conventional Spray | Suitable Use suitable proprietary equipment. Thinning may be required. |
Brush | Application by brush is recommended for small areas only. Multiple coats may be required to achieve specified film thickness. |
Roller | Application by roller is recommended for small areas only. Multiple coats may be required to achieve specified film thickness. |
Thinner | International GTA220 Thinning is not normally required. Consult the local representative for advice during application in extreme conditions. Do not thin more than allowed by local environmental legislation. |
Cleaner | International GTA822 |
Work Stoppages and Cleanup | Do not allow material to remain in hoses, gun or spray equipment. Thoroughly flush all equipment with International GTA822. Once units of paint have been mixed they should not be resealed and it is advised that after prolonged stoppages work recommences with freshly mixed units. Clean all equipment immediately after use with International GTA822. It is good working practice to periodically flush out spray equipment during the course of the working day. Frequency of cleaning will depend upon amount sprayed, temperature and elapsed time, including any delays. Do not exceed pot life limitations.All surplus materials and empty containers should be disposed of in accordance with appropriate regional regulations/legislation. |
Welding | In the event welding or flame cutting is performed on metal coated with this product, dust and fumes will be emitted which will require the use of appropriate personal protective equipment and adequate local exhaust ventilation. In North America do so in accordance with instruction in ANSI/ASC Z49.1 "Safety in Welding and Cutting." |
Safety
All work involving the application and use of this product should be performed in compliance with all relevant national Health, Safety & Environmental standards and regulations.
Prior to use, obtain, consult and follow the Material Safety Data Sheet for this product concerning health and safety information. Read and follow all precautionary notices on the Material Safety Data Sheet and container labels. If you do not fully understand these warnings and instructions or if you can not strictly comply with them, do not use this product. Proper ventilation and protective measures must be provided during application and drying to keep solvent vapour concentrations within safe limits and to protect against toxic or oxygen deficient hazards. Take precautions to avoid skin and eye contact (ie. gloves, goggles, face masks, barrier creams etc.) Actual safety measures are dependant on application methods and work environment.
Emergency contact numbers can be found in the Technical Data Sheet (TDS)
Limitations
This product will not cure adequately below 5°C. For maximum performance ambient curing temperatures should be above 10°C.
Overcoating information is given for guidance only and is subject to regional variation depending upon local climate and environmental conditions. Consult your local International Paint representative for specific recommendations.Apply in good weather. Temperature of the surface to be coated must be at least 3°C above the dew point. For optimum application properties bring the material to 21-27°C, unless specifically instructed otherwise, prior to mixing and application. Unmixed material (in closed containers) should be maintained in protected storage in accordance with information given in the STORAGE Section of this data sheet. Technical and application data herein is for the purpose of establishing a general guideline of the coating application procedures. Test performance results were obtained in a controlled laboratory environment and International Paint makes no claim that the exhibited published test results, or any other tests, accurately represent results found in all field environments. As application, environmental and design factors can vary significantly, due care should be exercised in the selection, verification of performance and use of the coating.
Volume (Liters) | Pack (Liters) | |
Intergard® 276 Part A | 16 | 20 |
Intergard® 276 Part B | 4 | 5 |
Storage
Lifetime at 25 °C
Minimum 12 Month(s)
Subject to re-inspection thereafter. Store in dry, shaded conditions away from sources of heat and ignition.
Diese Angaben stammen aus dem offiziellen Technischen Datenblatt von dem Lackhersteller. Wir übernehmen keine Gewährleistung für die Richtigkeit / fehlerhafte Angaben.
Wir bitten Sie, sich ausschließlich ans Technische Datenblatt des Herstellers zu halten, welches Sie weiter unten als PDF-Download finden.
All information were taken out of the Technical Data Sheet provided by the manufacturer. We don't garantuee the correctness of any information.
Please adhere solely to the Technical Data Sheet provided by the manufacturer which you can download as a PDF-File further below.