International, Ceilcote 680 Primer
inkl. MwSt. zzgl. Versandkosten
Sofort versandfertig, Lieferzeit ca. 1-3 Werktage
- Artikel-Nr.: KB10256
Vorteile
- Professionelle Beratung
- Schnelle Lieferung
- Großes Sortiment
Ceilcote® 680 Primer is a low viscosity epoxy primer for steel and concrete.
Intended Uses
As a primer for various Ceilcote schemes over both steel and concrete.
Colour | Clear |
Gloss Level | Not applicable |
Volume Solids | 100% |
Typical Thickness | 50-125 microns (2-5 mils) dry 50-125 microns (2-5 mils) wet |
Theoretical Coverage | 13.30 m²/litre at 75 microns d.f.t and stated volume solids |
Practical Coverage | Allow appropriate loss factors Coverage will vary according to individual systems and the configuration of the surface to be coated; consult the relevant Application Guidelines and specification for further information. |
Method of Application | Airspray, Roller, Brush |
Regulatory Data | |
Flash Point | Part A 97 °C Part B 108 °C Mixed >100 °C |
Product Weight | 1.08 kg/l (9.0 lb/gal) |
VOC-EU | 85 g/kg¹ |
¹ EU Solvent Emissions Directive (Council Directive 1999/13/EC)
Surface Temperature | 25 °C | 40 °C |
Touch Dry | 3 hrs | 2.5 hrs |
Hard Dry | 8.5 hrs | 3 hrs |
Overcoating Interval, Minimum | 5 hrs | 3 hrs |
Surface Preparation
All surfaces to be coated should be clean, dry and free from contamination. Prior to paint application all surfaces should be assessed and treated in accordance with ISO 8504:2000.
Oil or grease should be removed in accordance with SSPC-SP1 Solvent Cleaning.
Steel Substrates:
For immersion service or service in humid conditions or elevated temperatures, this product should be applied to surfaces which have been prepared by abrasive blast cleaning to Sa3 (ISO 8501-1:2007), SSPC SP5 or NACE #1. For dry environments abrasive blast cleaning to Sa2½ (ISO 8501-1:2007), SSPC SP10 or NACE #2 will be suitable. A minimum surface profile of 75 microns (3 mils) is required.
Ceilcote 680 Primer must be applied before oxidation of the steel occurs. If oxidation does occur the entire oxidised area should be reblasted to the standard specified above. Surface defects revealed by the blast cleaning process should be ground, filled or treated in the appropriate manner.
Concrete Substrates:
Concrete should be well cured prior to priming with the appropriate primer. The concrete surface should be dry and pass the plastic sheet test (ASTM D4263). All surfaces should be clean, dry and free from curing compounds, release agents, trowelling compounds, surface hardeners, efflorescence, grease, oil, dirt, old coatings and loose or disintegrating concrete. All concrete surfaces must also be abrasive blast cleaned to provide a roughened surface and remove laitance. The surface tensile strength (ASTM 4541) as prepared should be at least 2MPa (300 psi). Refer to the Concrete Surface Preparation Guidelines for more information.
Mixing | Material is supplied in two containers as a unit. Always mix a complete unit in the proportions supplied. Once the unit has been mixed it must be used within the working pot life specified. (1) Agitate Base (Part A) with a power agitator. (2) Combine entire contents of Curing Agent (Part B) with Base(Part A) and mix thoroughly with power agitator. |
Mix Ratio | 3 part(s) : 1 part(s) by volume |
Working Pot Life | 25 °C - 30 mins 40 °C - 20 mins |
Airless Spray | Not recommended. |
Air Spray (Conventional) | Suitable |
Brush | Recommended |
Roller | Recommended |
Thinner | Not suitable. Do not thin. |
Cleaner | Ceilcote T-410 Solvent MEK |
Work Stoppages | Do not allow material to remain in hoses, gun or spray equipment. Thoroughly flush all equipment with Ceilcote T-410 Solvent. Once units of paint have been mixed they should not be resealed and it is advised that after prolonged stoppages work recommences with freshly mixed units. |
Clean Up | Clean all equipment immediately after use with Ceilcote T-410 Solvent. It is good working practice to periodically flush out spray equipment during the course of the working day. Frequency of cleaning will depend upon amount sprayed, temperature and elapsed time, including any delays. All surplus materials and empty containers should be disposed of in accordance with appropriate regional regulations/legislation. |
Product Characteristics
The detailed Application Guidelines for the relevant Ceilcote system should always be consulted prior to use.
The Ceilcote 680 Primer application shall be conducted by the Applicator Company using employees trained in the appropriate application procedures. It is strongly advised that both application and application supervision is only carried out by professional personnel who have been trained in the correct use of the products.
The exact specification with regards to dry film thickness and number of coats will be provided by International Protective Coatings prior to application start up.
For concrete substrates where film integrity spark testing of lining and coating systems applied over Ceilcote 680 Primer is required, a conductive powder should be added. The type and quantity of powder per litre (and gallon) of mixed resin is as follows:
C-1 Powder 0.16 kg/l (1.3 lb/gal)
The powder must first be added and mixed into Part A resin prior to adding Part B.
Surface temperature must always be a minimum of 3°C (5°F) above dew point.
For all application steps, the surface temperature, air temperature and material temperature should be between 10ºC (50ºF) and 43ºC (110ºF).
Do not apply when relative humidity exceeds 90% or when condensation is likely to occur.
Dehumidification (DH) air conditioning and/or heating equipment may be necessary to control environmental conditions.
Consult International Protective Coatings for temperature limits for specific end use requirements.
Note:
VOC values are typical and are provided for guidance purpose only. These may be subject to variation depending on factors such as differences in colour and normal manufacturing tolerances.
Low molecular weight reactive additives, which will form part of the film during normal ambient cure conditions, will also affect VOC values determined using EPA Method 24.
Systems Compatibility
Ceilcote 680 Primer is designed for application to correctly prepared substrates.
It is compatible with various Ceilcote coatings and linings; consult International Protective Coatings or further advice.
Additional Information
Further information regarding industry standards, terms and abbreviations used in this data sheet can be found in the documents available at www.international-pc.com:
• Definitions & Abbreviations
• Surface Preparation
• Paint Application
• Theoretical & Practical Coverage
• Ceilcote 2000 Flakeline Application Guidelines
Safety Precautions
This product is intended for use only by professional applicators in industrial situations.All work involving the application and use of this product should be performed in compliance with all relevant national Health, Safety and Environmental standards, regulations and legislation.
Proper ventilation must be provided during application and afterwards during curing (refer to product datasheets for typical curing times) to ensure safe limits and prevent fires and explosions. Forced extraction will be required in confined spaces. Ventilation and/or respiratory personal protective equipment (airfed hoods or appropriate cartridge masks) must be provided during application and curing. Take precautions to avoid skin and eye contact (overalls, gloves, goggles, masks, barrier cream, etc).
Before use, obtain, read and then follow the advice given on the Material Safety Data Sheets (Parts A and B if two-pack) and the Health and Safety section of the Coatings Applications Procedures for this product.
In the event that welding or flame cutting is performed on metal coated with this product, dust and fumes will be emitted which will require the use of appropriate personal protective equipment and adequate local exhaust ventilation.
The detailed safety measures are dependent on application methods and the work environment. If you do not fully understand these warnings and instructions or if you cannot strictly comply with them, do not use the product and consult International Protective Coatings.
Volume (Liters) | Pack Sizes (Liters) | |
Ceilcote® 680 Primer Part A | 15 | 20 |
Ceilcote® 680 Primer Part B | 5 | 5 |
Storage
Lifetime at 25 °C
Minimum 12 Month(s)
Subject to re-inspection thereafter. Store in dry, shaded conditions away from sources of heat and ignition.
Diese Angaben stammen aus dem offiziellen Technischen Datenblatt von dem Lackhersteller. Wir übernehmen keine Gewährleistung für die Richtigkeit / fehlerhafte Angaben.
Wir bitten Sie, sich ausschließlich ans Technische Datenblatt des Herstellers zu halten, welches Sie weiter unten als PDF-Download finden.
All information were taken out of the Technical Data Sheet provided by the manufacturer. We don't garantuee the correctness of any information.
Please adhere solely to the Technical Data Sheet provided by the manufacturer which you can download as a PDF-File further below.